Explosion-proof light fitting zone 1,21

ORION

ELEKTROSVIT Svatobořice, a. s.

 

zone 1/21 Ex logo II 2G Ex de IIC T4-T6 Gb
zone 2/22 II 2D Ex tb IIIC Tmax. surface Db
for version "F"
zone 1/21 Ex logo II 2G Ex de IIB T4-T6 Gb
zone 2/22 II 2D Ex tb IIIC Tmax. surface Db

Use: Explosion-proof light fitting for the illumination of indoor and outdoor industrial spaces with a danger of gas, vapour and dust explosion.

Technical description: The body and flange of the light fitting are AlSi alloy castings finished with RAL 1005 powder paint. The optical cover is made of tempered glass. A steel suspension with an eye is fixed to the top part of the body. There are two cable outlets on the light fitting sides. The steel base plate with electrical equipment and reflector is built inside the light fitting. The light fitting is designed as a through light fitting, for two phase alternation (four-core cable). When the light fitting is used as a terminal light fitting, the free cable outlet is blinded with a plug. The max. cross-section of the connecting conductors is 4 mm2.

Installation: With a steel suspension with an eye ø18 mm or adjustable holder 3-99.6289

Versions: Standard light fittings are available with cable outlets M25x1.5, optionally with cable outlets M20x1.5.

To order: Shade 254.5021/01, protective basket 2-99.7461, holder 4-99.7995 for mounting on the ceiling, holder 338.2735 for mounting on the wall, adjustable holder 3-99.6289,  spanner 3-99.6158/1, blinding plug HSK-V-Ex M25x1.5, blinding plug HSK-V-Ex M20x1.5, screw plug V-Ex M25x1.5, screw plug V-Ex M20x1.5, screw plug V-Ms-VMQ-Ex M25x1.5, screw plug V-Ms-VMQ-Ex M20x1.5.

Downloads:

Type Recommended light source [W] Temperature class T max. of surface [°C] Voltage [V/Hz] Weight [kg]
511 37 02 Halogen bulb Philips EcoClassic 140 T4 101 230 / 50 8,5
511 37 02 Halogen bulb Philips EcoClassic 105 T5 90 230 / 50 8,5
511 37 02 Halogen bulb Philips EcoClassic 70 T6 77 230 / 50 8,5
511 37 02 Compact fluorescent tube OSRAM DULUX EL Longlife 23 T6 59 230 / 50 8,5
511 37 02 Compact fluorescent tube Philips Master PL Electronic 23 T6 63 230 / 50 8,5
511 37 02 Compact fluorescent tube Phil. Master PL Electronic Globe 23 T6 58 230 / 50 8,5
511 37 02 Bulb CLAS 200 T4 104 230 / 50 8,5
511 37 02 Bulb CLAS 150 T5 92 230 / 50 8,5
511 37 02 Bulb CLAS 60-100 T6 80 230 / 50 8,5
511 37 02 Blended lamp HWL 160 T5 90 230 / 50 8,5
541 33 03 High-pressure mercury discharge lamp HQL 80 T4 95 230 / 50 8,5
541 33 03 High-pressure sodium discharge lamp NAV-E 50/I T6 81 230 / 50 8,5
541 33 04 High-pressure mercury discharge lamp HQL 125 T4 121 230 / 50 9
541 33 04 High-pressure sodium discharge lamp NAV-E 110/I T4 99 230 / 50 9
541 33 06 High-pressure sodium discharge lamp NAV 70 T5 86 230 /50 8,5
541 33 06 High-pressure halide lamp HQI 70 T6 80 230 / 50 8,5
581 04 02 Compact fluorescent tube DULUX D 26 T6 60 230 / 50 8,5
511 37 02 t Halogen bulb Philips EcoClassic 140 T4 111 230 / 50 8,5
511 37 02 t Halogen bulb Philips EcoClassic 105 T4 100 230 / 50 8,5
511 37 02 Halogen bulb Philips EcoClassic 70 T5 87 230 / 50 8,5
511 37 02 t Bulb CLAS 200 T4 114 230 / 50 8,5
511 37 02 t Bulb CLAS 150 T4 102 230 / 50 8,5
511 37 02 t Bulb CLAS 60-100 T5 90 230 / 50 8,5
511 37 02 t Blended lamp HWL 160 T4 100 230 / 50 8,5
541 33 03 t High-pressure mercury discharge lamp HQL 80 T4 105 230 / 50 8,5
541 33 03 t High-pressure sodium discharge lamp NAV-E 50/I T4 91 230 / 50 8,5
541 33 04 t High-pressure mercury discharge lamp HQL 125 T3 131 230 / 50 9
541 33 04 High-pressure sodium discharge lamp NAV-E 110/I T4 109 230 / 50 9
581 04 02 t Compact fluorescent tube DULUX D 26 T6 70 230 / 50 9
511 37 02 F Halogen bulb Philips EcoClassic 140 T4 101 230 / 50 8,5
511 37 02 F Halogen bulb Philips EcoClassic 105 T5 90 230 / 50 8,5
511 37 02 F Halogen bulb Philips EcoClassic 70 T6 77 230 / 50 8,5
511 37 02 F Bulb CLAS 200 T4 104 230 / 50 8,5
511 37 02 F Bulb CLAS 150 T5 92 230 / 50 8,5
511 37 02 F Bulb CLAS 60-100 T6 80 230 / 50 8,5
511 37 02 F Blended lamp HWL 160 T5 90 230 / 50 8,5
541 33 04 F High-pressure mercury discharge lamp HQL 125 T4 121 230 / 50 8,5
541 33 04 F High-pressure sodium discharge lamp NAV-E 110/I T4 99 230 / 50 8,5
*By adding letter "K" behind type designation, light fittings will be provided with protective steel baskets (511 37 02 K, 511 37 02 KF)